Cerner Order Name Comp C4 Complement C4
Performing Laboratory
St. Louis Children's Hospital
Lab Dept
Core Lab Chemistry
Specimen Requirements
Specimen Type: Blood
Container/Tube
Preferred: Light green-top (lithium heparin) Vacutainer
Acceptable: green SAMPLETTE/MICROTAINER, plain red-top vacutainer, or Gold/Red SST gel vacutainer.
Collection Volume: 1.0 mL (minimum 0.6 mL)
Patient Preparation: None
Sample Rejection: Mislabeled or unlabeled specimens.
Special Instructions: Send to lab promptly.
Logistics
Test Availability: Monday-Sunday
Cut-off time: None; performed as received
Turnaround Time: Same day; 2 hours from receipt in lab
Lab Testing Section: Chemistry
Interpretive
Reference Range:
<1 Years: 5.0-30.0 mg/dL
≥ 1 Years: 10.0-40.0 mg/dL
Critical Values: No critical value established
Limitations: In very rare cases gammopathy, in particular type IgM (Waldenstrom's macroglobulinemia), may cause unreliable result.
Methodology: Immunoturbidimetric Assay
Additional Information
For SLCH Laboratory use only
Lab Processing instructions: Centrifuge specimen to separate. If specimen is collected in microtainer or plain, red-top tube aliquot sample into a conical tube for testing (labeling aliquot with specimen type).
Processed Volume: minimum 0.3 mL plasma/serum
Analyte Stability:
Ambient - unprocessed: 8 hours
PROCESSED:
Ambient: 2 days
Refrigerated: 2 days
Frozen: NA
Notes: Will also accept EDTA plasma
General Information
EPIC order name: Complement C4 (EPIC Test # LAB5780)
Cerner order name: Comp C4
CPT Codes: 86160
LOINC Value: 4498.2
Synonyms: Fourth Component of Complement
Last Reviewed
November 2024